3200BEP Strobe          
Explosion-Proof Strobe


 
3200BEPThe 3200BEP family of single flash explosion-proof UL listed strobe lights is designed for operation in hazardous areas rated Class I Group C & D (gas hazards) and Class II Group E, F, & G (dust hazards). Division 2 locations are defined by the NFPA as described at the bottom of this page. Design features include a housing made of die cast high strength copper-free aluminum alloy with a baked powder epoxy finish, stainless steel hardware, o-ring sealed prestressed glass globe with double pitch acme threads for smooth assembly and ease of maintenance, and an optional guard which need not be removed for relamping. 3/4” conduit hubs are standard.


$893.27
Features

 
  • Single flash
  • Xenon strobe lamp
  • Available in amber, blue, clear, green, and red
  • 2 year warranty on power supply
  • 1 year warranty on lamp
  • UL listed (where noted below)

3000 Models

 
  
Pendant Mount Flange Mount Wall Mount

 
ModelDescriptionVoltage
3150BEP–PM3/4” pendant mount12 – 74VDC
3200BEP–PM3/4” pendant mount120VAC
3300BEP–PM3/4” pendant mount240VAC
3150BEP–FM3/4” flange mount12 – 74VDC
3200BEP–FM3/4” flange mount120VAC
3300BEP–FM3/4” flange mount240VAC
3150BEP–WM3/4” wall mount12 – 74VDC
3200BEP–WM3/4” wall mount120VAC
3300BEP–WM3/4” wall mount240VAC

Specifications

 
ItemDescription
Lamp Type700–R1–COLOR ( please specify lens color )
Voltage and Amperage12–74VDC draws 1.25A @ 12VDC tampering to 0.2A @ 74VDC
120/240VAC draws 0.17A @ 120VAC
(50/60Hz) draws 0.075A @ 240VAC
Temperature CodeT6–Class I Groups C and D
T4A–Class II Groups E, F, & G
Temperature Range–40° C to +55° C
Power Supply Output13 watts standard, 11 watts for model 3150
9 joules per flash standard, 8 joules per flash for model 3150
Flash Rate85 flashes per minute
Size and Weight13.69” tall x 7.44” dia. x 10.6 lbs
( 347mm x 188mm x 4.7kg )


NFPA Definitions

Class I, Division 2.
A location (1) in which volatile flammable liquids or flammable gases are handled, processed or used, but in which the liquids, vapors or gases will normally be confined within closed containers or closed systems from which they can escape only in case of accidental rupture or breakdown of such containers or systems, or in case of abnormal operation of equipment; or (2) in which ignitable concentrations of gases or vapors are normally prevented by positive mechanical ventilation, and which might become hazardous through failure or abnormal operation of the ventilating equipment; or (3) that is adjacent to a Class I Division 1 location, and to which ignitable concentrations of gases or vapors might occasionally be communicated unless such communication is prevented by adequate positive–pressure ventilation from a source of clean air and effective safeguards against ventilation failure are provided. [See Section 500–4(b) of NFPA 70, National Electrical Code.]

Class II, Division 2.
A location in which (1) combustible dust will not normally be in suspension in the air in quantities sufficient to produce explosive or ignitable mixtures and dust accumulations are normally insufficient to interfere with the normal operation of electrical equipment or other apparatus; or (2) dust may be in suspension in the air as a result of infrequent malfunctioning of handling or processing equipment and dust accumulations resulting there from may be ignitable by abnormal operation or failure of electrical equipment or other apparatus. [See Section 500–5 (b) of NFPA 70, National Electrical Code.]

 

Copyright [2008] [Eclipse Logistics, LLC LTD]. All rights reserved. EclipsePublicSafety.com©